Technical Advice | Glazing Technologies

Passivhaus and Glazing

Summarise with:

Copilot

Copy this prompt, then open Copilot:

Open Copilot
Rebecca Clayton

Written by Rebecca Clayton

Edited by Dan Finnegan

Fact-checked by Michal Piekarewicz

Aug 19, 2026

Last verified: Aug 19, 2026

Next review: Aug 19, 2026

Our Editorial Process - How We Write Our Technical Advice Articles

01

We pick topics from real questions we hear or see being asked

We do not make up topics just to get clicks. Our topics come from the questions people really ask us. Architects ask us when they plan a building. Builders ask us on-site. Homeowners ask us when they plan their project. If the same question keeps coming up, we write about it.

02

One of our internal experts writes the first draft

The first draft is written by someone who works with that glazing system. This might be a technical advisor, a designer, or a product expert.

They write using three things, in this order. First, our own finished projects and what we learned from them. Second, the building rules and the glass standards that apply. Third, the maker's technical data for the system we supply. When we give a number or a limit, we say where it comes from. We name the rule or standard and link to the official source so you can check it yourself.

03

A second expert checks it

Before any article goes live, a second qualified person reads it. They check three things. That the facts are right and not made too simple. That any rule or standard we mention is current and stated correctly. That the advice matches how the work is really done on site.

This checker can send the article back, ask for proof, or stop it from going live. Two experts must agree. This is the most important safety step in how we work. The name of the person who checked each article is shown on the article itself.

04

We publish it, review it periodically and make fresh content updates to ensure ongoing accuracy

Each article shows who wrote it, who checked it, and the date it was last checked. Rules, standards, and products change over time. So we go back and review our advice on a regular basis. We update it when a rule changes, a standard is replaced, or a product changes. Being right matters more than leaving an old article alone.

About Passivhaus

Passivhaus is an energy performance standard that is fast growing in popularity and usage worldwide. Its focus is to reduce the need for heating and cooling systems within buildings, thereby lowering its energy consumption whilst also creating good indoor clean air. The method this is achieved through is simple: thorough insulation and an airtight building.

The Passivhaus standard was developed in Germany in the 1990’s with the first buildings achieving it being built in Darmstadt in 1991. It can be used in residential builds, as well as commercial and industrial. In builds that are completed to the Passivhaus standard, there is no longer any requirement for a traditional central heating system.

The building is also able to remain cool in the same way. In addition to this, excellent air quality is achieved by reducing air infiltration rates. Passivhaus is equally as effective in both warm and cool climates.

passivhaus_1_img

Passivhaus and Glazing

In order to achieve the Passivhaus standard, it is vital that all doors and windows are correctly fitted to stop any draughts. The windows are triple glazed with a U value of 0.79. The frames are thermally broken as opposed to solid wood and the insulation prevents cold getting into the house. The external edges of the frame are covered in insulation and covered with external cladding, creating a clean and simple finish. Internally the windows are usually finished with timber and have a high standard of Italian fittings. Due to the high levels of insulation the windows only open internally.

In addition, buildings that achieve the Passivhaus standard can reduce their carbon emissions by up to 80% and energy consumption by up to 85%. This all means that energy bills can be significantly lowered when the Passivhaus standard is achieved.

passivhaus_small_1