Technical Advice | Building Regulations and Planning Permissions
Building Regulation Part K for Glazing – Requirement K4
Summarise with:
Copilot
Copy this prompt, then open Copilot:
Technical Advice | Building Regulations and Planning Permissions
Summarise with:
Copilot
Copy this prompt, then open Copilot:
01
We do not make up topics just to get clicks. Our topics come from the questions people really ask us. Architects ask us when they plan a building. Builders ask us on-site. Homeowners ask us when they plan their project. If the same question keeps coming up, we write about it.
02
The first draft is written by someone who works with that glazing system. This might be a technical advisor, a designer, or a product expert.
They write using three things, in this order. First, our own finished projects and what we learned from them. Second, the building rules and the glass standards that apply. Third, the maker's technical data for the system we supply. When we give a number or a limit, we say where it comes from. We name the rule or standard and link to the official source so you can check it yourself.
03
Before any article goes live, a second qualified person reads it. They check three things. That the facts are right and not made too simple. That any rule or standard we mention is current and stated correctly. That the advice matches how the work is really done on site.
This checker can send the article back, ask for proof, or stop it from going live. Two experts must agree. This is the most important safety step in how we work. The name of the person who checked each article is shown on the article itself.
04
Each article shows who wrote it, who checked it, and the date it was last checked. Rules, standards, and products change over time. So we go back and review our advice on a regular basis. We update it when a rule changes, a standard is replaced, or a product changes. Being right matters more than leaving an old article alone.
Approved document K of the Building Regulations outlines the requirements for protection from falling, collision and impact. This article will focus on requirement K4 which covers protection against impact with glazing.
Requirement K4 outlines building regulations for both residential dwelling and public or non-residential buildings. The regulations only apply to glazing that people are likely to come into contact with whilst moving around the building, entering or exiting.
Glazing that building occupants are likely to come into contact with must meet one of three requirements:
Using toughened glass is one way to ensure the glass will break in a way that is unlikely to injure anyone, as these panes shatter into rounded, extremely small pieces.
Toughened glass also creates glazing that resists impact without breaking. For a stronger pane, laminated glass can also be used.
To shield or protect the glazing from impact, the amount of contact people have with the glazing can be lowered or a barrier can be placed around the glazing.
Glazing that is between floor and shoulder height (usually doors and side panels) near handles and push plates pose the biggest threat to people, as pushing or shoving them to open if they stick can cause the glazing to shatter and injure people.

The shaded areas of the diagram show critical locations to which the requirements outlined in K4 apply.
For the shaded areas, the glazing must comply with one of the following:

Many systems can be designed to comply with these regulations through the use of toughened glass.
Safe breakage is based on impact resistance. As defined in BS EN 12600 section 4 and BS 6206 clause 5.3, in an impact test the breakage is considered safe if:
Any glazing that meets the requirements for BS EN 12600 Class 3 or BS 6206 Class B is considered suitable for these critical locations. Glazing is also considered suitable when it is installed in a door or door side panel with a pane width of over 900mm and it meets the requirements for BS EN 12600 Class 2 or BS 6206 Class B.
When using float glass there are restrictions on size, as this type of glass breaks into large sharp pieces when broken upon impact.
IQ use toughened glass as standard on all glazing systems to ensure that in the event of breakage the glass breaks into smaller pieces that are less likely to injure people.
Two pieces of toughened glass can also be laminated which would hold the shattered panes in place if the glazing is in a location where it is likely to be impacted upon.

Glazing in the aforementioned critical areas do not need to comply with the requirements in K4 if they are protected by a permanent screen.
The screen does need to meet certain requirements for this to be the case.
The permanent screen would need to prevent a sphere of 75mm from impacting the glazing, so bars that are spaced further than 75mm apart would not be adequate.
The permanent screen must also be robust, so cannot be made of a material that is flexible or easily broken.
Lastly, the screen must be difficult to climb so if using bars they must be vertical bars, not horizontal.
For more information get in touch with the IQ team who will be able to assist you with the glazing for your project.